Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Tuberculosis and Respiratory Diseases ; : 609-613, 1998.
Article in Korean | WPRIM | ID: wpr-197647

ABSTRACT

21-year-old male was admitted for evaluation of a mass shadow on chest film. On chest computed tomography showed 5 cm sized homogeneous low density based on the second thoracic vertebral body in the posterior mediastinum. The patient had been performed thoracic sympathectomy 6 months before admission and oxidized cellulose was used for hemostasis at that operation Surgical resection was performed and microscopic result was foreign body granuloma caused by oxidized cellulose. Oxidized cellulose is an absorbable sterile mesh and used to control capillary or venous bleeding. Although the manufacturer recommends its removal after hemostasis is achieved, in clinical practice it is usually left in situ to reabsorb spontaneously, usually with no untoward effect.


Subject(s)
Humans , Male , Young Adult , Capillaries , Cellulose, Oxidized , Foreign Bodies , Granuloma, Foreign-Body , Hemorrhage , Hemostasis , Mediastinum , Sympathectomy , Thorax
2.
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 719-723, 1997.
Article in Korean | WPRIM | ID: wpr-63960

ABSTRACT

We experienced a case of aneurysm of the sinus of Valsalva dissecting into the ventricular dseptum. This dissection was induced by paravalvular leakage after aortic and mitral valve replacement. This 37-year-old male was admitted via emergency room due to progressive dyspnea. He had undergone aortic valve replacement(carbomedic(R) 23 mm) and mitral valve replacement(carbomedic(R) 31 mm) due to aortic regurgitation and mitral regurgitation about 6 years prior to admission and followed up regularly. The diagnosis was made by transthoracic and transesophageal echocardiography and reconfirmed by root aortography. The inlet of the ventricular septal aneurysmal sac was repaired by one layer suture with 3-0 prolene of the endocardium, epicardium and homograft muscle shoulder altogether. Postoperative course was uneventful and the patient was discharged on the 11th postoperative day.


Subject(s)
Adult , Humans , Male , Allografts , Aneurysm , Aortic Valve , Aortic Valve Insufficiency , Aortography , Bays , Diagnosis , Dyspnea , Echocardiography, Transesophageal , Emergency Service, Hospital , Endocardium , Mitral Valve , Mitral Valve Insufficiency , Pericardium , Polypropylenes , Shoulder , Sinus of Valsalva , Sutures , Ventricular Septum
3.
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 57-65, 1992.
Article in Korean | WPRIM | ID: wpr-159974

ABSTRACT

No abstract available.


Subject(s)
Follow-Up Studies , Prostheses and Implants
4.
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 371-375, 1991.
Article in Korean | WPRIM | ID: wpr-19084

ABSTRACT

No abstract available.

5.
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 843-852, 1991.
Article in Korean | WPRIM | ID: wpr-159486

ABSTRACT

No abstract available.


Subject(s)
Arrhythmias, Cardiac , Heart , Thoracic Surgery
SELECTION OF CITATIONS
SEARCH DETAIL